MASTER

Master remote controls have two versions of the operating commands: digital up to 6-step joysticks, or analogical and proportional step-less joysticks . Analogical manoeuvers cab be adjusted by the operator from the transmitter, independently for each manoeuvres. The receiver has an LCD display reporting system status ,providing greater safety and agility if anomalies are detected. It also has an RS-485 serial port which can be use to connect to PLC’s ,robots, variators or any peripheral equipment that requires information through the serial port. It incorporates a multi-frequency, synthesized radio system taht enables the operator to automatically change the working channel. These units accept several operation configurations depending on each application.

MASTER/SLAVE: Two transmitters control two receivers. PITCH & CATCH: Two transmitters control one receiver. DATA FEED BACK: Bi-directional equipment.

TECHNICAL DESCRIPTION

Number of Commands DIGITAL: 12/20/28 + Start -Stop – Horn
DIGITAL/ANALOGICAL:14-4/22-8 + Start -Stop-Horn
Responding Time <=50 ms
Active Emergency Responding Time <50 ms
Passive Emergency Responding Time 1,900 ms
Operating Range Distance 200m /656 ft

TRANSMITTER

Operating Range Frequency UHF (865.000-867.000 MHZ)
Other frequencies available.
UHF (865.00 to 867.00 MHZ)
Channel Spacing 25 KHz
Modulation FM
RF Power Output 10mW A.R.P
Coding Key FFSK
Transmitting Power Consumption 80mA
Standby Power Consumption <800 µA
Operating Working time(20°C/68°F) 11 Hours + 30 Minutes after low – battery led flashes.
Battery Capacity and type Ni-MH Battery 7.2V ,1500 mAh
Battery Weight 200g /0.44 lb
Casing Material Polyamide 6-6 reinforced with 15% fiberglass.
Transmitter Approx. Weight 1.5 Kg/3.30 lb
Indicator Leds Transmission Indicator and low-battery on separate leds.
Operating Commands Two dual-axis fully proportional and analogical step-less joysticks or digital upto 6 steps (combinations available)
Protection Rating Ip65

RECEIVER

RF Sensitivity 03 µV at 12 dB S/N
Outputs DIGITAL: by relays 5 A 30 Vdc/5 A, 250 Vac with resistive load (Cos =1) Comm. Port Rs-485 ANALOGICAL: by tension:bipolar (0-5 Ø V, 5 V, 0-10 V, 10 V)and unipolar (2/4/6V, 3/6/9 V, 6/12/18 V), ±± other values adjustable from the transmitter by the operator
Power Requirements 48VAC/110VAC/230VAC (available 24 Vdc/12 Vdc)
Display LCD display matrix 2 x 16 reporting system status
Consumption 16 relays 0.14 A at 230Vac/0.29 A at 110 Vac/0.7 A at 48 Vac
32 relays 0.18 A at 230Vac/0.35 A at 110 Vac/0.9 A at 48 Vac
Casing Material Polyamide 6-6 reinforced with 30% fiberglass.
Dimensions 16 relays 255 x 200 x 95 mm/10.04 x 7.87 x 3.74 in
32 relays 315 x 235 x 120 mm/12.40 x 9.25 x 4.72 in
Weight 2.8 Kg (6×17 lb) (16 relays) / 4.2 kg (9.48 lb) (32 relays)
Protection rating Ip65
Ambient Temperature -20 C to 70°C

BATTERY CHARGER

Power requirements 230 Vac (Optional 110 Vac)
Dimensions 73 x 69 x 72 mm/2.87 x 2.71 x 2.83 in
Battery Charging time 4-6 hours
Temperature 0°C to 40°C /32° F to 104° F
Weight 200g/0.44 lb